Parameter Name / value range / [default seng] Info
0x2631:015
(P400.15)
Funcon list: Acvate AI2 setpoint
(Funcon list: Setp: AI2)
•
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 532
Assignment of a trigger for the "Acvate AI2 setpoint" funcon.
Trigger = TRUE: analog input 2 is used as setpoint source (if the trigger
assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
4Analog input 2 ^ 601
0 Not connected
Example for operang mode
•
The keypad is set as standard setpoint source.
•
Switch S1 starts the motor in forward direcon of rotaon. Switch S1 in the inial posion
stops the motor again.
•
Switch S2 switches the direcon of rotaon.
•
Switch S3 acvates analog input 1 as setpoint source.
•
Switch S4 acvates analog input 2 as setpoint source.
If S3 and S4 are operated at the same me, the analog input 1 is acve as set-
point source since the digital input 3 assigned to this funcon has a higher prior-
ity than the digital input 4.
Connecon plan funcon
GND
AI1
AI2
AO1
10V
24V
DI1
DI2
DI3
DI4
DI5
DO1
X3
S1 S2 S3 S4
1k ...10k
R1
R2
0 ... 10 V
Potenometer R1 Frequency setpoint selecon via AI1
Potenometer R2 Frequency setpoint selecon via AI2
Switch S1 Run
Switch S2 Reverse rotaonal direcon
Switch S3 Acvate AI1 setpoint
Switch S4 Acvate AI2 setpoint
Parameter Name Seng for this example
0x2631:001 (P400.01) Enable inverter Constant TRUE [1]
0x2631:002 (P400.02) Run Digital input 1 [11]
0x2631:004 (P400.04) Reset fault Not connected [0]
0x2631:013 (P400.13) Reverse rotaonal direcon Digital input 2 [12]
0x2631:014 (P400.14) Acvate AI1 setpoint Digital input 3 [13]
0x2631:015 (P400.15) Acvate AI2 setpoint Digital input 4 [14]
0x2631:018 (P400.18) Acvate preset (bit 0) Not connected [0]
0x2824 (P200.00) Control selecon Flexible I/O conguraon [0]
0x2838:003 (P203.03) Stop method Standard ramp [1]
0x2860:001 (P201.01) Frequency control: Default setpoint source Keypad [1]
Flexible I/O conguraon
Setpoint change-over
Analog input setpoint source
549