SC Tables
SM Appendix 3-1 M065/M066
Appendix:
Service Call
Conditions
3. APPENDIX: SERVICE CALL CONDITIONS
3.1 SC TABLES
3.1.1 SERVICE CALL CONDITIONS
Summary
The "SC Table" section shows the SC codes for controller errors and other errors. The
latter (not controller errors) are put into four types. The type is determined by their reset
procedures. The table shows the classification of the SC codes.
Key Definition Reset Procedure
Controller
errors
CTL
The error has occurred in the
controller.
See "Troubleshooting Procedure"
in the table.
Other errors
A
The error involves the fusing
unit. The machine operation is
disabled. The user cannot reset
the error.
Turn the main switch off and on.
Reset the SC (set SP5-810-1).
Turn the main switch off and on.
B
The error involves one or some
specific units. The machine
operates as usual, excluding
the related units.
Turn the operation switch off and
on.
C
The error is logged. The
SC-code history is updated.
The machine operates as
usual.
The SC will not show. Only the
SC history is updated.
D
The machine operation is
disabled. You can reset the
machine by turning the
operation switch or main switch
off and on. If the error occurs
again, the same SC code is
displayed.
Turn the operation switch or main
power switch off and on.