SC Tables
M065/M066 3-44 SM Appendix
3.1.8 SC8XX: OVERALL SYSTEM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
816
CTL
D
Energy saving I/O sub-system error
The energy saving I/O sub-system detects an error.
 Controller board defective
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
817
CTL
D
Monitor Error
00FE File Detection/Electronic Signature Check Error
 The boot loader failed to read the signature of one or more of the
following files on the boot SD card:
1) Self-diagnostic module, 2) Kernel, 3) Root file system.
One or more of these files in the flash ROM or on the SD card is
false, missing, or revised.
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
819
CTL
C
Fatal kernel error
Due to a control error, a RAM overflow occurred during system
processing. One of the following messages was displayed on the
operation panel.
[0x5032] HAIC-P2 error
 System program defective
 Controller board defective
 Optional board defective
Replace controller firmware
[0x6261] HDD error
[554C] USB error
⇒
Rev. 03/16/2011