4.4 STO (Basic/Extended)
Definition according to EN 61800-5-2:
"The STO function prevents energy from being
supplied to the motor, which can generate a tor‐
que."
Select STO
STO
Y
W
Examples of how the function can be used
Example Possible solution
It is only permissible to open a protective door if the
motor torque has been switched off.
Select STO in the converter.
The pulses are suppressed and the motor
coasts to a standstill.
How does STO function in detail?
The converter recogni‐
zes the selection of
STO via a failsafe input
or via the safe commu‐
nication PROFIsafe.
The converter then
safely switches off the
torque of the connected
motor.
7KHPRWRUWRUTXHLV
VZLWFKHGRII
6SHHG
672GHVHOHFWLRQ
352),VDIHFRQWURO
ZRUG
672
W
W
4.4.1 Details and parameterization
In conjunction with a machine function or in the event of a fault, the "Safe Torque Off" (STO)
function is used to safely disconnect the torque-generating energy supply to the motor.
A restart is prevented by the two-channel pulse suppression. The switching on inhibited
prevents an automatic restart after deselection of STO.
The two-channel pulse suppression function integrated in the Motor Modules / Power Modules
is the basis for this function.
Safety functions integrated in the drive
4.4 STO (Basic/Extended)
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB 105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK MC and is the answer not in the manual?

Siemens SINUMERIK MC Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK MC
CategoryControl Systems
LanguageEnglish

Related product manuals