4.15.1.6 Sequence
SBT has the following basic sequence:
7HVWWRUTXH
6LJQ
VHOHFW SRVLWLYH
7HVWWRUTXH
PRQLWRULQJ
5DPSWLPH7HVW
GXUDWLRQ
5DPSWLPH
%UDNHFORVHG
'LDJQRVWLFV
PD[WHVW
WRUTXH
%UDNHWHVWWRUTXH
'LDJQRVLV
6WDWLF
ORDGWRUTXH
0RQLWRUSRVLWLRQWROHUDQFH
(QDEOH
RSHUDWLRQ
(QDEOH
RSHUDWLRQ
%UDNHWHVWVHOHFWHG
6HWSRLQWLQSXW
([WHUQDO
6HWSRLQWLQSXW
([WHUQDO
6HOHFWEUDNHWHVW
6WDUWEUDNHWHVW
'HVHOHFWEUDNHWHVW
Q6HWSRLQWLQSXWGULYH
VHW
ORDG
0
VHW
0
W
Figure 4-23 SBT: Time sequence
After the user selects the brake test (0/1 edge in r10231.0), the static hanging load is
determined. For this reason, all brakes must be open and the pulses enabled when the
brake test is selected.
When testing a motor holding brake, which is directly controlled from SINAMICS, the
brake is automatically opened when the pulses are enabled and p1215=1.
When testing an external brake, via p10234.6 or for SIC/SCC, via S_ZSW3B.6, a value
of 0 indicates that the external brake must be opened. This must occur within 11
seconds, otherwise the test is canceled and a fault is output.
The brake, the test sequence and the test direction are then selected by the user.
When the brake test is active after the start of the brake test / brake test sequence by the
user (0/1 edge in r10231.1), the holding brake (MHB) is closed or there is a prompt to close
the external brake. The request to close the brake is again indicated with p10234.6 = 1 or
S_ZSW3B.6 = 1. Also in this case, only a maximum of 11 seconds must elapse, otherwise
a fault is issued.
The test torque (test torque ± load torque for a vertical axis) is specified during the SBT.
When n = 0 is entered, the controller builds up an appropriate test torque against the closed
brake. The test torque is built up along a ramp. The ramp is defined by the time of p10208.
At the end of the test sequence, the brake is opened or there is a prompt to open the brake.
Safety functions integrated in the drive
4.15 SBT
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB 177

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK MC and is the answer not in the manual?

Siemens SINUMERIK MC Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK MC
CategoryControl Systems
LanguageEnglish

Related product manuals