08/2012
2-47
WorkCentre 5021/5019
093-312, 093-912
Status Indicator RAPs
Initial Issue
093-312 Toner Dispense Motor Rotation Fail
BSD-ON:CH9.3
Regardless of low usage of toner from Toner Cartridge, it was detected to be empty.
Cause/Action
Check the following:
• The Toner Cartridge for improper installation
• The Toner Dispense Motor (Output Check [092-001]) for operation failure. (PL 8.2)
• The Toner transport path for Toner blockage.
• The Drive Gear for wear and damage.
If no problem is found, replace the following parts in sequence:
• Toner Cartridge (PL 8.1)
• ESS/MCU PWB (PL 18.1)
093-400 Toner Near Empty
BSD-ON:CH9.3
The Toner Cartridge needs to be replaced soon.
Cause/Action
The Toner Cartridge needs to be replaced soon. Replace the Toner Cartridge as required. (PL
8.1)
093-406 Toner Pre Near Empty
BSD-ON:CH9.3
Preparation for replacing the Toner Cartridge is required.
Cause/Action
The Toner Cartridge needs to be replaced soon. Prepare a new Toner Cartridge.
Replace the Toner Cartridge as required. (PL 8.1)
093-912 Toner Empty
BSD-ON:CH9.3
The toner must to be replaced as it has ran out.
Cause/Action
Replace the Toner Cartridge. (PL 8.1)
093-956 Drum New CRU Installation Fail
BSD-ON:CH9.3
During the developing powder installation mode after installing the Drum Cartridge, the ATC
Measured Value is found to be abnormal. (Seal not removed)
Cause/Action
1. Remove the developing powder seal from the Drum Cartridge.
2. If the problem persists after removing the seal, replace the Drum Cartridge. (PL 8.1)
093-959 Drum New CRU Installation Fail Exceeds
Thresholding Times
BSD-ON:-
The number of developing powder installation mode executions has exceeded the upper limit.
Cause/Action
Replace it with the correct Drum Cartridge. (PL 8.1)