232 Actual signals and parameters
2506 CRIT SPEED 3
LO
See parameter 2502 CRIT SPEED 1 LO. 0.0 Hz /
1rpm
0.0…500.0 Hz /
0…30000 rpm
See parameter 2502.1 = 0.1Hz
/ 1 rpm
2507 CRIT SPEED 3
HI
See parameter 2503 CRIT SPEED 1 HI. 0.0 Hz /
1rpm
0.0…500.0 Hz /
0…30000 rpm
See parameter 2503.1 = 0.1Hz
/ 1 rpm
26 MOTOR
CONTROL
Motor control variables
2601 FLUX OPT
ENABLE
Activates/deactivates the flux optimization function. Flux
optimization reduces the total energy consumption and
motor noise level when the drive operates below the
nominal load. The total efficiency (motor and the drive) can
be improved by 1% to 10%, depending on the load torque
and speed. The disadvantage of this function is that the
dynamic performance of the drive is weakened.
OFF
OFF Inactive 0
ON Active 1
2602 FLUX
BRAKING
Activates/deactivates the Flux braking function. See section
Flux braking on page 138.
OFF
OFF Inactive 0
ON Active 1
All parameters
No. Name/Value Description Def/FbEq

Table of Contents

Other manuals for ABB ACS355

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS355 and is the answer not in the manual?

ABB ACS355 Specifications

General IconGeneral
Input Voltage200 V to 240 V AC, 380 V to 480 V AC
Frequency47 Hz to 63 Hz
Control MethodScalar control
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Communication InterfacesModbus RTU, CANopen
Enclosure RatingIP20
Operating Temperature-10°C to +50°C (14°F to 122°F)
Storage Temperature-40°C to +70°C (-40 to +158 °F)
Humidity95% RH (non-condensing)
AltitudeUp to 1000 m (3280 ft) without derating