7 C9400-LC-48UX 4 accepted 350 189 203 350 15
-- Fan Tray 0 accepted 350 -- -- 350 --
--- -------------------- -------- -------- ------ ------------- ---- ------ -----
Total 2030
Device# show power detail
Power Fan States
Supply Model No Type Capacity Status 1 2 3 4
------ -------------------- ---- -------- ------------ -----------------------
PS1 C9400-PWR-3200AC AC 3200 W active good good good good
PS2 C9400-PWR-3200AC AC 3200 W active good good good good
PS3 C9400-PWR-3200AC AC 3200 W active good good good good
PS4 C9400-PWR-3200AC AC 3200 W active good good good good
PS5 C9400-PWR-3200AC AC 3200 W active good good good good
PS6 C9400-PWR-3200AC AC 3200 W active good good good good
PS7 C9400-PWR-3200AC AC 3200 W active good good good good
PS8 C9400-PWR-3200AC AC 3200 W active good good good good
PS Current Configuration Mode : Combined
PS Current Operating State : Combined
Power supplies currently active : 8
Power supplies currently available : 8
Power Summary Maximum
(in Watts) Used Available
------------- ------ ---------
System Power 2030 2030
Inline Power 106 23570
------------- ------ ---------
Total 2136 25600
Automatic Linecard Shutdown : Enabled
Power Budget Mode : Dual Sup
autoLC Power Out of In
Mod Model No Priority State Budget Instantaneous Peak Reset Reset
--- -------------------- -------- -------- ------ ------------- ---- ------ -----
1 C9400-LC-24XS 0 accepted 200 87 88 200 10
2 C9400-LC-48T 1 accepted 65 35 43 65 5
3 C9400-SUP-1 0 accepted 400 235 253 400 130
4 C9400-SUP-1 0 accepted 400 235 253 400 130
5 C9400-LC-48T 2 accepted 65 35 37 65 5
6 C9400-LC-24XS 3 accepted 200 87 88 200 10
7 C9400-LC-48UX 4 accepted 350 189 203 350 15
-- Fan Tray 0 accepted 350 -- -- 350 --
--- -------------------- -------- -------- ------ ------------- ---- ------ -----
Total 2030
Power Management Considerations
It is possible to configure a switch that requires more power than the power supplies provide.
• The power requirements for the installed modules exceed the power provided by the power supplies.
• If the switch has a single power supply module that is unable to meet power requirements, the
following error message is displayed:
System Management Configuration Guide, Cisco IOS XE Bengaluru 17.4.x (Catalyst 9400 Switches)
231
Environmental Monitoring and Power Management
Power Management Considerations