TROUBLESHOOTING c-7
C-7 [E2:12] Disconnection in
[E2:14] Disconnection in
displayed
[E2:15] Disconnection in
displayed
[E2:16] Disconnection in
displayed
LS select solenoid system is displayed
pump merge-divider solenoid system is
2-stage relief solenoid system is
travel speed solenoid system is
*
*
*
*
*
*
This troubleshooting is carried out when there is still an abnormality, so when disconnecting the
connector and inserting the T-adapter, or when removing the T-adapter and returning the connector
to its original position, if the service code is not displayed, the problem has been removed.
If there is a disconnection in the solenoid or wiring harness, the solenoid is not actuated.
If the No. 2 pin of the solenoid is short circuiting with the ground, the solenoid continues to be actuated.
If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON, operate according
to Condition 2 in Table 1, and check if any service code is displayed. (If it is not displayed, the problem has
been removed.)
Before carrying out troubleshooting, check that all the related connectors are properly inserted.
Always connect any disconnected connectors before going on to the next step.
Check that fuse 1 is normal.
3
Is voltage between
ya each pin for
2 - troubleshooting 3
F GotoA
in the table 1 _
Is resistance
normal?
YJZJ between each pin
- for troubleshooting - l Turn starting
1
2 in the table 1
switch ON.
- normal?
. When ON: Max. 3V
When OFF: 20 - 30V
Interchange wiring
with other solenoid.
. Turn starting
l Operate according to Condition 1.
Is applicable service
- switch OFF.
NO
code displayed?
l Disconnect
connector VO2,.VO3, VO5,
or V06, whichever is
-Turn starting
switch OFF.
applicable.
t
* Interchange wiring. NO
-Turn starting
switch ON again.
- Operate according
to Condition 2.
5 YES
Is applicable
Is resistance
l Turn starting
NO
between each pin
switch ON.
- for troubleshooting -
4 in the table 1
. Operate
NO normal?
according to
Condition 2.
)
*Turn starting
NO
switch OFF.
* Disconnect COl.
Cause
kre of following solenoids is
lefective
i2:12 . LS select solenoid
L2:14 . . . Pump merge-divider
solenoid
i2:15 . . 2-stage relief
solenoid
i2:16 . . Travel speed
solenoid
Iefective pump controller
Disconnection in applicable
wiring harness between CO1
female) (101, (11) - CO1 (31,
4), (14) or (6). or applicable
wiring harness between
solenoid (2) - CO1 (3). (4).
14) or (6) shortcircuiting
nrith ground
ieplace
leplace
tepair or
eplace
20-182
0
classicmachinery.net

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu PC210LC-6 and is the answer not in the manual?

Komatsu PC210LC-6 Specifications

General IconGeneral
BrandKomatsu
ModelPC210LC-6
CategoryExcavators
LanguageEnglish

Related product manuals