TROUBLESHOOTING
M-l 1
b)
r63
(coolant level) flashes
Cause
Remedy
- See Item M-7 a). -
cl
09
(coolant temperature) flashes
Cause
Remedy
2 YES
When short
Defective coolant
-
ym connector is
temperature sensor
, F connected to PO7 -
system (see M-21)
_ (female) does
Is coolant
display go out?
temperature
_ -Start engine. NO
Defective monitor panel
Replace
gauge in red
range?
. Start engine
and run at half * Defective monitor panel
Replace
throttle or
above.
M-l 1 c) Related electric circuit diagram
PO2
HO3
E08
(04016)
(516)
(SWP14 1 PO7(X2)
Coolant temperature sensor
Monitor
panel
X08DD171
20-255