Digital Tiles Continuous Cardiac Output (CCO) & Continuous Hemodynamics (Optional)
1 - 10 Addendum to V Series Operating Instructions
1.4.2 About the CCO Tile
The CCO tile displays all CCO in units of l/min with a resolution of 0.1 l/min.
If the CCO measurement is invalid, “- -” displays in place of digits.
1.4.3 CCO Alarms
Refer to the "Configuring CCO/Hemo Alarms" on page 1-4 for additional information.
1.4.4 Message Area
The message area provides information about the current state of the CCO parameter. If there is more
than one message to display, the messages scroll.
MESSAGE DETAILS
CCO High Alarm Violation Indicates that the current value is either equal to or higher than the set alarm
limits
.
CCO Low Alarm Violation Indicates that the current value is either equal to or lower than the set alarm
limits
.
CCI High Alarm Violation Indicates that the current value is either equal to or higher than the set alarm
limits
.
CCI Low Alarm Violation Indicates that the current value is either equal to or lower than the set alarm
limits
.
T Blood High Alarm Violation Indicates that the current value is either equal to or higher than the set alarm
limit
s
.
T Blood Low Alarm Violation Indicates that the current value is either equal to or lower than the set alarm
limit
s
.
SVR High Alarm Violation Indicates that the current value is either equal to or higher than the set alarm
limit
s
.
SVR Low Alarm Violation Indicates that the current value is either equal to or lower than the set alarm
limit
s
.
SVRI High Alarm Violation Indicates that the current value is either equal to or higher than the set alarm
limit
s
.
SVRI Low Alarm Violation Indicates that the current value is either equal to or lower than the set alarm
limit
s
.
Check Vigilance Indicates there is an error on the Edwar
d
s device that is not a physiological
alarm. It is a prompt for the clinician to look at the Edwards device for more
detailed information.

Table of Contents

Other manuals for Mindray V12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray V12 and is the answer not in the manual?

Mindray V12 Specifications

General IconGeneral
BrandMindray
ModelV12
CategoryMedical Equipment
LanguageEnglish

Related product manuals