Description
A2-17
a
MONITOR/SCAN
Key
and Light
(contd.)
ln the
monitor
mode,
The
system displays
the
temperature
of only the
zone currently
selected.
lf
the system-ready
time
delay feature is
active
and
is
currently
selected
for
monitoring,
the
system shows
the number
of
minutes
remaining
until
the system
is ready
for operation.
a
a
The
MONITORiSCAN
light
stays on
STANDBY
Key and
Light
Pressing
the
STANDBY key
when the
HEATERS tight
is on takes
the
system
into
or out of
the standby
mode. When
the standby
feature is
active,
o
The
STANDBY light
turns
on.
o
The
READY light
turns
off.
.
The
pump
turns
ofi.
.
Temperatures
on allzones
drop
untilthe temperature
of each zone
reaches
the
preselected
standby
temperature.
o
The HEATERS
light remains
on.
lf
the HEATERS
light
is not
on,
you
cannot
place
the
system in
the
standby mode.
When
the standby
feature
is
disabled,
o
The
STANDBY light
turns
off.
o
The heaters
turn on
and all zones
begin heating.
lf the
auto-energize
pump
feature
is
active, the
pump
turns on either
when
the system
reaches
the ready
condition
or when
the tank
reaches
the temperature
you
have
specified.
After
all zones
have
reached
their
preselected
setpoint
temperature,
the
READY light
turns
on.
a
@
1999 tlordson
Corporation
All rights
reseryed
41-3000y
lssued
2/99
A2EN43-[3V-4-AXXVI-2

Table of Contents

Other manuals for Nordson 3100V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson 3100V Series and is the answer not in the manual?

Nordson 3100V Series Specifications

General IconGeneral
BrandNordson
Model3100V Series
CategoryMelting Machines
LanguageEnglish

Related product manuals