Line Modules Booksize
4.7 Basic Line Modules with cold plate
Booksize Power Units
264 Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Please note the following before mounting a Basic Line Module with cold plate onto a
customer-specific heat sink:
● Before mounting, check the surface of the heat sink to ensure that it is not damaged.
● To improve heat transfer, a heat-conducting medium must be used. Special spherical-
indented heat-conducting foil must be used for this purpose. Every Basic Line Module
cold plate is supplied with heat-conducting foil cut to the right size. Note the mounting
position of the heat-conducting foil (see figures below).
Also replace the heat-conducting foil when replacing a component.
Only use heat-conducting foil released or supplied by Siemens.
Table 4- 61 Overview of heat-conducting foils
Heat-conducting foil, 100 mm
Heat-conducting foil, 150 mm
Heat-conducting foil, 200 mm
Note
M6 studs and hexagon nuts or grub screws (ISO 7436
-M6x40-14 H, property class 8.8) are
recommended for mounting the components.