Motor Modules Booksize
6.3 Motor Module with external air cooling
Booksize Power Units
426 Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Table 6- 29 Technical data Double Motor Modules Booksize (3 to 18 A)
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
) 40%
max
A
ACrms
A
A
ACrms
ACrms
2 x 2.6
2 x 3.5
2 x 4.3
2 x 6
2 x 7.7
2 x 10
2 x 15.3
2 x 24
d max
DC
Overvoltage trip
2)
V
DC
820 ± 2 %
DC
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
A
DC
A
DC
100
150
100
150
100
150
100
150
3)
Based on I
n
(600 VDC; 4 kHz)
H
kW
2 x 1.6
2 x 2.7
2 x 4.8
2 x 9.7
(including electronics losses, see Power loss
W 97,6 132,6 187,6 351,2
without derating
kHz
4
without derating
° C
40
3
Max. permissible heat sink temperature
Applies only to order numbers with x = 0 .. 3
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
parameterized rated voltage
3)
Rated power of a typical standard induction motor at 400 V 3 AC.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com