Motor Modules Booksize
6.3 Motor Module with external air cooling
Booksize Power Units
426 Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
6.3.7.2
Double Motor Modules
Table 6- 29 Technical data Double Motor Modules Booksize (3 to 18 A)
External air cooling
6SL3121-
2TE13-0AAx
1)
2TE15-0AAx
1)
2TE21-0AAx
1)
2TE21-8AAx
Output current
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
) 40%
Peak current (l
max
)
A
ACrms
A
A
ACrms
A
ACrms
2 x 3
2 x 2.6
2 x 3.5
2 x 6
2 x 5
2 x 4.3
2 x 6
2 x 10
2 x 9
2 x 7.7
2 x 10
2 x 18
2 x 18
2 x 15.3
2 x 24
2 x 36
Output voltage
V
ACrms
0 … 480
DC-link current I
d max
A
DC
7,2
12
22
43
DC-link voltage
V
DC
510 … 720
DC-link capacitance
μF
110
220
220
705
Overvoltage trip
Undervoltage trip
2)
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics power supply
V
DC
24 (20,4 … 28,8)
Electronics current drawn
at 24 VDC
A
DC
1,15
1,15
1,15
1,3
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
A
DC
A
DC
A
100
150
20
100
150
20
100
150
20
100
150
20
Unit rating
3)
Based on I
n
(600 VDC; 4 kHz)
Based on I
H
kW
kW
2 x 1.6
2 x 1.4
2 x 2.7
2 x 2.3
2 x 4.8
2 x 4.4
2 x 9.7
2 x 8.2
Total power loss
(including electronics losses, see Power loss
tables (Page 781))
W 97,6 132,6 187,6 351,2
Max. pulse frequency
without derating
with derating
kHz
kHz
4
16
Max. ambient temperature
without derating
with derating
° C
° C
40
55
Sound pressure level
dB(A)
< 60
< 60
< 60
< 60
Cooling air requirement
m
3
/h
29,6
29,6
29,6
56
Max. permissible heat sink temperature
° C
80
85
89
90
Weight
kg
5,8
5,8
5,7
8,6
1)
Applies only to order numbers with x = 0 .. 3
2)
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
parameterized rated voltage
3)
Rated power of a typical standard induction motor at 400 V 3 AC.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 6SL3120-2TE21-0AA3 and is the answer not in the manual?

Siemens 6SL3120-2TE21-0AA3 Specifications

General IconGeneral
BrandSiemens
Model6SL3120-2TE21-0AA3
CategoryPortable Generator
LanguageEnglish

Related product manuals