Motor Modules Booksize
6.3 Motor Module with external air cooling
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
423
Note
If the cooling air requirement is not covered by the filtered fan, the components cannot
output their specified power.
The filters with filter fan must be regularly checked for dirt and cleaned if necessary.
Table 6- 27 Technical data Single Motor Modules Booksize (3 to 30 A)
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
)
40%
A
ACrms
A
A
ACrms
A
ACrms
2,6
3,5
6
4,3
6
10
7,7
10
18
15,3
24
36
25,5
40
56
V
ACrms
0 … 0.717 x DC-link voltage
d max
DC
DC
Overvoltage trip
Undervoltage trip
2)
V
DC
V
DC
820 ± 2 %
380 ± 2 %
DC
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
A
DC
A
DC
DC
100
150
100
150
100
150
100
150
100
150
3)
Based on I
n
(600 VDC; 4 kHz)
kW
1,6
2,7
4,8
9,7
16
(including electronics losses,
see Power loss tables
W 50,4 73,4 100,4 185,4 309,2
without derating
kHz
4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com