Functions
6.23 [3.10] Maintenance & Diagnostics > Save/load parameter set
Operating with the Local User Interface
234 Operating Manual, 06/2017, A5E31930478-05
See also
Save parameter set (Page 234)
Load parameter set (Page 235)
6.23.2
Save parameter set
Procedure
1. Main menu > "3. Maintenance and diagnostics" > "10. Save/load parameter set" >
"1. Save parameter set"
Use this function to save the current parameter assignment in the device. The data is
saved as "user data".
2. Start save process: "Save parameter set" parameter box.
Follow the instructions in the displayed window.
When the procedure is completed, the "Save data" window appears on the display.
You will find Information on the restoring the original parameter assignment at: → Load
parameter set (Page 235).