Services Modbus gateway
IX14 User Guide
389
---------------
State : enabled
Source : 192.168.2.3
Latitude : 44* 55' 14.809" N (44.92078)
Longitude : 93* 24' 47.262" w (-93.413128)
Altitude : 279 meters
Velocity : 0 meters per second
Direction : None
Quality : Standard GNSS (2D/3D)
UTC Date and Time : Thurs, 03 March 2022 10:16:23 03
No. of Satellites : 7
>
3. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Show geofence information
1. Log into the IX14 command line as a user with Admin access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. Use the show location geofence command at the system prompt:
> show location geofence
Geofence Status State Transitions Last Transition
------------- ------ ------ ----------- ---------------
test_geofence Up Inside 0
>
3. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Modbus gateway
The IX14 supports the ability to function as a Modbus gateway, to provide serial-to-Ethernet
connectivity to Programmable Logic Controllers (PLCs), Remote Terminal Units (RTUs), and other
industrial devices. MODBUS provides client/server communication between devices connected on
different types of buses and networks, and the IX14 gateway allows for communication between
buses and and networks that use the Modbus protocol.
This section contains the following topics:
Configure the Modbus gateway 390
Show Modbus gateway status and statistics 403