If device names have been changed on the ECC800 WebUI, the changes will be synchronized to the
NetEco. If device names have been changed on the NetEco, the changes will not be synchronized to
the ECC800 WebUI.
If device names have been changed on the NetEco, device name modification on the ECC800
WebUI will not be synchronized to the NetEco any more.
Step 5 Click in the upper area of the page to save device information.
After the ECC800 device is bound, select the ECC800 device in the left navigation tree. Then, change
the authentication password in the Management Info area so that the password on the ECC800 WebUI
is the same as that on the NetEco for the ECC800 to connect to the NetEco properly. The preset
authentication password for the ECC800 device is Modifyme_123.
Perform the following operations on the Modify page:
1.
Enter the new password in the New password and Confirm password text boxes.
2.
Perform the following operations as required in the Send To Device column.
If YES is selected, change and synchronize the authentication passwords for the ECC800 and
ECC800 WebUI synchronized on the server so that the authentication passwords on both sides are
the same.
If NO is selected, change the authentication password for the ECC800 synchronized on the server.
3.
Click OK.
You are advised to change the password once every three months
Step 6 You can perform the following operations after clicking the device icon:
Select Manage under to view Overview.
----End
6.5.2.3 Setting the Transparent Transmission Function for the ECC800
Collector
Context
Using the transparent transmission function, the NMS can directly manage southbound
components that are not monitored by the ECC800.
In this example, the COM2 port of the ECC800 is used for transparent transmission.
Procedure
Step 1 Log in to the ECC800 WebUI as an administrator.
Step 2 Choose System Settings > NMS Application > Transparent Transmission Channel.
Step 3 Set COM2(Port:3212) to Enable and click Submit.
Mapping relationship: COM1 corresponds to port 3211, COM2 port 3212, COM3 port 3213, and COM4
port 3214.
If the port is set for the first time, you are prompted to set an authentication password.
On the Set Authentication Password tab page, set Authentication password and
Confirm authentication password and click Submit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei iManager NetEco 6000 and is the answer not in the manual?

Huawei iManager NetEco 6000 Specifications

General IconGeneral
BrandHuawei
ModeliManager NetEco 6000
CategoryServer
LanguageEnglish

Related product manuals