Technical Information
101
DGC 6xxx
After 12 hours with convection or combination operation, the appliance
switches off automatically.
Cause:
Appliance has not been switched off.
Remedy:
No remedy required. The appliance is ready for operation.
3.10 Fault Code F60 - Power Electronic Temperature Limit Exceeded
Symptom:
Temperature of power electronic (N1-1) is too high.
Cause:
Insufficient cooling and venting.
Remedy:
1. Check cooling and venting using the service mode; see Section 060-4.2.
2. Check the wiring harness.
3. Replace the wiring harness, if necessary.
4. Install a new cooling fan, if necessary. See Section 045-4.1.
3.11 Fault Code F74 – Drain Valve Fault
Cause:
Drain valve not functioning at steam generator.
Remedy:
Replace the drain valve; see Section 035-4.6.
3.12 Fault Code F94 - Plumbed-Water Connection Water Intake Fault
Cause:
After opening valves 1Y63/2Y63 no water intake was registered by water tank
reed switch B3-18.
3.13 Fault Code F190 - Plumbed-Water Connection Valve Defective
Cause:
Water intake okay at valve test. 1 valve defective.
3.14 Fault Code F191 - Heat-Flow Pt1000 Temperature Sensor Short-
Circuited
Cause:
Temperature sensor (2R30-10) or wiring harness short-circuited.
Remedy:
1. Check the wiring harness.
2. Replace the heat-flow temperature sensor with its wiring harness. See
Section 030-4.9.