Technical Information
113
DGC 6xxx
Note:
After it is begun, the accessing procedure must be completed within 10
seconds.
1. Press and hold the Timer touchpad.
2. Press the touchpad once.
3. Release the Timer touchpad.
4. Immediately press and release the Timer touchpad 5 times and on the
5th time hold it until the programming mode is indicated.
Acknowledgement indicator:
The display shows Program mode and various programming functions.
Options:
See Section 060-4.1 for instructions on menu navigation.
Submenu Function Options
Reset
Yes All settings
modified by the
customer (except
the language) will
be reset. All
customized
programs will be
deleted. Demo
mode is
deactivated. The
fault memory
remains saved.
No
Service
Restart OK A restart is
equivalent to a
break in the
power supply.
The fault memory
and all settings
and programming
carried out by the
customer remain
unchanged.
Cancel
Cavity size Oven interior XL
Oven interior XXL
Appliance type Main water connection (DGC
67xx/68xx only)
Present
Not present
Lift-up control panel 1-key operation
2-key operation
Current
consumption
Max. 16A
Max. 3x10A
Descaling Descaling reset? Yes/No Descaling
counter reset to
zero
1
Table 060-5: Programming Functions
1
After service work has been completed, the appliance should be descaled.