3.7 Fascia Panel Is Crooked
Symptom:
In the closed position, one side of the panel is not resting against the
appliance front. In the open position, the panel is not level.
Cause:
Gears are positioned unequally in the guide rails.
Remedy:
Position the gears equally in the guide rails.
3.8 Float Stuck in Water Tank
Symptom:
Float(s) and chamber cover are stuck in the water tank.
Cause:
Inadequate adhesion between float chamber and cover.
Series modification:
None at the moment. The welding technique for adhering the cover to the
float chamber has been improved. The chamber has also been enlarged in
order to prevent the float from jamming. Series modification effective after
machine no. 111340154.
Remedy:
Replace the water tank.
Note:
The inventory in the replacement-parts warehouse has been simplified so
that now only the improved water tank is available.
Install a water tank with the following material numbers (or higher):
Water tank: mat. no. 8577101 (check the parts CD first)
Condensate tank: mat. no. 8577081 (check the parts CD first)
3.9 Fascia Panel Does Not Respond When Sensor Is Pressed
Symptom:
Fascia panel does not respond when sensor is pressed. A confirmation tone
can be clearly heard, but the fascia panel will not open or close.
Cause:
Software fault. If the fascia panel is closed and then a sensor is pressed
within the next half-second, this creates an undefined condition in the
software.
Series modification:
New firmware update, ID 2531 to 2534.
Remedy:
1. Firmware update to ID 2531 or higher.