GPS7 GPS Synchronization and Timecode module
INPUT-OUTPUT.
Use the left (◄)orright(►) arrow button configure the
BLACK 1 connector as an INPUT or an OUTPUT (if allowed). This connector
is forced to be an input if the TIMING REFERENCE SOURCE is set to a Genlock
signal or if VITC is the TIME OF DAY reference.
NOTE. If a reference signal is connected to the BLACK 1 / REF IN connector, you
should configure this connector as an input so that the GPS7 module does not
output a vid
eo signal if the Reference Source is changed to GPS or internal.
This might occur when using the GPS7 module in a dual-configuration where the
moduleisb
eing switched between being a slave via g enlock to incoming video or
a master source using the GPS/GLONASS reference.
This menu
selection is available only when BLACK 1 is selected for configuration
and the GPS7 module has the BLACK 1 / REF IN connector.
FORMAT. Use the left (◄)orright(►) arrow b utton to select from the signal
formats in the following table. Press the ENTER button to confirm the selection.
Table 3-21: GPS7 module output signal formats
Commo
n
Non-integer HD trilevel
sync r
ate
1
Integer HD trilevel sync
rate
1
NTSC
1080 59.94i 1080 60i
NTSC
-J
1080
23.98sf
1080 50i
PAL 1080 29.97p
1080
24sf
CW 1
0MHz
2
1080 23.98p 1080 30p
720 59.94p 1080 25p
1080 24p
72
0 60p
720 50p
1
The signal formats available in this submenu depend on the HD trilevel sync rate setting (non-integer or integer),
which is set using the Select Output selection in the GPS7 module main menu. (See page 3-113, GPS7 module
main menu.)
2
The CW 10 MHz format is available on the BLACK 3 output only.
F
IELD REFERENCE. Use the left (◄)orright(►) arrow button to Enable or
Disable the field reference in the output signal. Press the ENTER button to
confirm the selection.
NOTE. This submenu is available only when a non-HD format is set as the signal
format of the selected BLACK output.
TG8000 Multiformat Test Signal Generator User Manual 3–123