can be added to the RVP8. And since the delivered SITE stubs are thrown
away and replaced with their customized versions, the long term
maintenance of both the Vaisala portions and developer portions of the
RVP8 code are assured.
D.2.2 Installing Incremental RDA
Upgrades
RDA development systems are upgraded in the same manner as standard
operational systems using the procedures described in the Vaisala
Software Installation Manual. The only difference is that you have a little
more work to do afterward to continue running your custom code under the
new RDA release.
The RDA upgrade replaces the RVP8/Main and RVP8/Proc SITE libraries
with their default stubs, so you will need to rebuild your customizations.
Since the executables are built from the OPEN trees, the simplest method
is to copy those newly released OPEN areas alongside your existing SITE
directories. Your entire development cycle can then be carried out entirely
from the /home/operator area, without ever having to compile in the
/usr/sigmet tree directly.
$ cd /home/operator/src/rda
$ rm –rf rvp8main/open rvp8main/core rvp8proc/open
rvp8proc/core
$ cp –pr /usr/sigmet/src/rda/rvp8main/open rvp8main
$ cp –pr /usr/sigmet/src/rda/rvp8proc/open rvp8proc
$ make clean
$ make –j2
$_make -j2 install
You are rebuilding your code under the new header files that were just
installed during the upgrade. You are likely to find a few minor
incompatibilities in the form of changed structure definitions and/or
changed function prototypes. Check the header file documentation as well
as the current Vaisala RDA Release Notes to find out what changes need to
be made. The RVP8 will not let you run with incompatible headers. Some
You may receive a RVP8/Main startup errors such as:
RVP8/Main code version mismatch
Core: Version=2.12 Build=298
Open: Version=2.12 Build=298
Site: Version=2.11 Build=295

Table of Contents

Other manuals for Vaisala RVP900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaisala RVP900 and is the answer not in the manual?

Vaisala RVP900 Specifications

General IconGeneral
BrandVaisala
ModelRVP900
CategoryReceiver
LanguageEnglish