Startup Procedure and Test Run
4
4.5 Automatic Parameter Settings Optimized for Specific Applications (Application Presets)
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference 167
4.5 Automatic Parameter Settings Optimized for Specific
Applications (Application Presets)
The bypass has application presets to set the necessary parameters for different applications to their best values. To
examine the parameters that A1-06 [Application Preset] automatically changed, use [User Custom Parameters] on the
Main menu.
Note:
Make sure that you set A1-03 = 2220 [Initialize Parameters = 2-Wire Initialization] to initialize parameters before you set A1-06.
This section shows the procedure to set an application preset.
1. Push (Home) to show the HOME screen.
Note:
• The keypad will show [Home] in the top right corner when the HOME screen is active.
• If [Home] is not shown on , push (Back) to show [Home] on .
2. Push (Menu).
3. Push or to select [Parameters], then push .
4. Push or to select [A Initialization Parameters], then push .
5. Push or to select [A1 Initialization], then push .

Table of Contents

Other manuals for YASKAWA HV600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA HV600 and is the answer not in the manual?