5.1 A: Initialization Parameters
174 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
5.1 A: Initialization Parameters
A parameters [Initialization Parameters] set the operating environment and operating conditions for the drive.
â—† A1: Initialization
A1 parameters set the operating environment and operating conditions. For example, these parameters set the keypad
language and the parameter access level.
â– A1-00: Language Selection
No.
(Hex.)
Name Description
Default
(Range)
A1-00
(0100)
RUN
Language Selection Sets the language for the HOA keypad. 0
(0, 5)
Note:
When you initialize the drive with parameter A1-03 [Initialize Parameters], the drive will not reset this parameter.
0 : English
5 : Spanish
â– A1-01: Access Level Selection
No.
(Hex.)
Name Description
Default
(Range)
A1-01
(0101)
RUN
Access Level Selection Sets user access to parameters. The access level controls which parameters the keypad will display
and which parameters you can set.
2
(0 - 4)
0 : Operation Only
Access to A1-00 [Language Selection], A1-01, A1-04 [Password], and the U Monitors.
1 : User Parameters
Access to A1-00, A1-01, A1-04, and parameters registered to A2-01 to A2-32 [User Parameters 1 to 32].
2 : Advanced Level
Access to all parameters, but not Expert Mode parameters.
3 : Expert Level
Access to all parameters including Expert Mode parameters.
4 : Lock Parameters
Parameters that you can see are the same as Advanced Level, but parameters that you can change are only A1-01 and
A1-04.
The keypad will show the message [Parameters Locked]:
• In the HOME screen, the keypad will show the message [Parameters Locked] on the second line.
• If you try to change a parameter setting, the keypad will show the warning [LOCK] [Parameters Locked] for 2 s.
To clear this warning, push one of the keys on the keypad.