2-232
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
SIP600_PARSING_ENGINE Messages
Error Message %SIP600_PARSING_ENGINE-3-MASTER_ABORT: Parsing Engine CPU Master Abort
Error
Explanation
The SIP-600 parsing engine has detected a CPU master abort interrupt. A read-only to
write-only register or a write-only to read-only register could cause this interrupt. The parsing
engine continues to process data from the interfaces, if possible.
Recommended Action If traffic resumes, no action is required. If this message recurs, copy the
message exactly as it appears on the console or in the system log. Research and attempt to resolve
the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages,
these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open
a case with the Technical Assistance Center via the Internet at
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the information you have gathered. Attach the
following information to your case in nonzipped, plain-text (.txt) format: the output of the show
logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message %SIP600_PARSING_ENGINE-3-PARITY_ERROR: Parsing Engine CPU Parity Error
Explanation
The SIP-600 parsing engine has detected a CPU parity error. Suspect a hardware fault
on the second occurrence of this message. Otherwise, the parsing engine continues to process data
from the interface, if possible.
Recommended Action If traffic resumes, no action is required. If this message recurs, copy the
message exactly as it appears on the console or in the system log. Research and attempt to resolve
the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages,
these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open
a case with the Technical Assistance Center via the Internet at
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the information you have gathered. Attach the
following information to your case in nonzipped, plain-text (.txt) format: the output of the show
logging and show tech-support commands and your pertinent troubleshooting logs.
Error Message %SIP600_PARSING_ENGINE-3-RP_INT_WATCHDOG_TIMEOUT: Parsing Engine RP
Interface Watchdog Timeout
Explanation
The SIP-600 parsing engine has detected an RP interface watchdog timeout. The RP
interface process has not relinquished the processor for the watchdog timeout period. The parsing
engine continues to process data from the interfaces if possible.
Recommended Action If traffic resumes, no action is required. If this message recurs, copy the
message exactly as it appears on the console or in the system log. Research and attempt to resolve
the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages,
these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open
a case with the Technical Assistance Center via the Internet at
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the information you have gathered. Attach the
following information to your case in nonzipped, plain-text (.txt) format: the output of the show
logging and show tech-support commands and your pertinent troubleshooting logs.