2-15
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
C6K_PLATFORM Messages
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
C6K_PLATFORM-4
Error Message %C6K_PLATFORM-4-CONFREG_BREAK_ENABLED : The default factory setting
for config register is 0x2102.It is advisable to retain 1 in 0x2102 as it prevents
returning to ROMMON when break is issued.
Explanation
The SP configuration register has been changed from the default factory setting of
0x2102 to another hexadecimal value.
Recommended Action No action is required.
Error Message %C6K_PLATFORM-4-ENVMON: System shutdown due to temperature alarms is
[chars].
Explanation
The system has a configuration to shut down a module if its operating temperature
exceeds a temperature threshold. This configuration has been bypassed, and a module will still
operate in an over-temperature condition. Operating at an over-temperature condition can damage
the hardware.
Recommended Action Do not override the sensor alarms that act on an over-temperature condition.
Enter the environment-monitor shutdown temperature command to bring the system back to
standard temperature detection.
Error Message %C6K_PLATFORM-4-RTC_OSCILLATOR: The oscillator in the Real Time Clock
is [chars]. Calendar [chars] be maintained during the powered down state of the
switch.
Explanation
A command has been entered that will cause the system calendar not to be maintained
during a power down of the switch. The system date and time will require manual setting when the
system is powered up during the next boot time. This command is useful to conserve the battery
power of the CMOS, which is used to keep the real-time clock active while the switch is powered
down. This condition is useful only if the switch is powered down for a long period of time.
Recommended Action If the switch need not be powered down for a long period of time, remove the
configuration by entering the no hw-module rtc-oscillator shutdown command.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco III - Supervisor Engine III and is the answer not in the manual?

Cisco III - Supervisor Engine III Specifications

General IconGeneral
BrandCisco
ModelIII - Supervisor Engine III
CategorySoftware
LanguageEnglish

Related product manuals