Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
CARDMGR Messages
Error Message %CAPI_EC-4-SLOT_RATE_LIMITED: Adding interfaces on slot [dec] to an
etherchannel will limit channel throughput to 1 Gbps!
Explanation
Because ports on the indicated slot use oversubscription, the total throughput of the port
channel is limited.
Recommended Action If more throughput is required, either use ports from a line card that does not
use oversubscription, or use ports from different line cards or port groupings on oversubscribed line
cards. For example, if the line card has 48 ports in groups of eight, you can select ports 1, 9, 17, 25,
33, and 41 for the same port channel.
CARDMGR Messages
This section contains SIP 400 Card Manager (data plane) (CARDMGR) messages.
CARDMGR-2
Error Message %CARDMGR-2-ESF_DEV_ERROR: An error has occurred on [chars]: [chars]
Explanation
The Express Services Forwarding (ESF) encountered an error during normal operation.
Steps must be taken to resolve the problem and allow traffic through the SIP 400 line card.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
Error Message %CARDMGR-2-ESF_LOAD_FAIL: [chars] failed to load: [chars]
Explanation
The ESF could not be loaded because one of the steps in the startup sequence failed.
This ESF is now not operational, which stops the traffic through the SIP-400 line card.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.