2-63
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
CONST_DIAG Messages
Error Message %CONST_DIAG-4-DIAG_SUGGEST_ACTION_DUE_TO_FABRIC_CHAN_LOW_RATE: Flow
control is occurring in the system. Analyze the system traffic and remove the
traffic source that causes flow control.
Explanation
The diagnostic test has detected a low buffer rate for the fabric channel. Flow control is
occurring in the system.
Recommended Action Analyze the system traffic and remove the traffic source that is causing flow
control. Enter the show fabric utilization command to determine the overall traffic pattern.
Error Message %CONST_DIAG-4-HM_TEST_WARNING: [chars] will occur after [dec]
consecutive failures
Explanation
The system has detected an unrecoverable error.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
CONST_DIAG-6
Error Message %CONST_DIAG-6-DIAG_ONDEMAND_NOT_SUPPORTED: [chars] is not supported
on-demand for module [dec]
Explanation
The specified on-demand online diagnostics are not supported on the specified module.
Recommended Action This message is informational. No action is required.
Error Message %CONST_DIAG-6-DIAG_RERUN_RESET: Resetting Module [dec] to re-run
[chars] diagnostic
Explanation
The system is resetting the module to rerun diagnostics.
Recommended Action This message is informational. The system is working properly.
Error Message %CONST_DIAG-6-HM_MESSAGE: High traffic/CPU util seen on Module [dec]
[SP=[dec]%,RP=[dec]%,Traffic=[dec]%]
Explanation
The system bypassed the health-monitoring test on the specified module because of high
utilization of system resources.
Recommended Action This message is informational. No action is required.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco III - Supervisor Engine III and is the answer not in the manual?

Cisco III - Supervisor Engine III Specifications

General IconGeneral
BrandCisco
ModelIII - Supervisor Engine III
CategorySoftware
LanguageEnglish

Related product manuals