EasyManuals Logo
Home>Cisco>Software>III - Supervisor Engine III

Cisco III - Supervisor Engine III User Manual

Cisco III - Supervisor Engine III
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
2-48
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
OL-11469-02
Chapter 2 Messages and Recovery Procedures
CAPI Messages
CAPI Messages
This section contains card application program interface (CAPI) messages.
CAPI-2
Error Message %CAPI-2-INVALID_SLOT_NUM: Invalid slot number [dec], Expected value is
between [dec] and [dec]
Explanation
The system detected an internal software inconsistency that might affect the operation
of one or more modules.
Recommended Action Use the hw-module command to reload or power cycle any modules that are
not operating correctly. If this message recurs, copy the message exactly as it appears on the console
or in the system log. Research and attempt to resolve the issue using the tools and utilities provided
at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
Error Message %CAPI-2-INVALID_SPA_BAYNUM: SPA subslot number [dec] is invalid for
slot [dec]
Explanation
The system detected an internal software inconsistency that might affect the operation
of the SPA in the slot and subslot specified in the error message.
Recommended Action If the configuration for the SPA in the slot and subslot specified in the error
message has not been loaded from the startup-configuration, use the copy nvram:startup-config
system:running-config command after the SPA carrier has loaded to apply the configuration. Note
that the interfaces will be configured as shutdown; enter the no shutdown command to restart the
affected interfaces. If the operation of the given SPA is affected in other ways, use the hw-module
command to reload or power cycle the module. If this message recurs, copy the message exactly as
it appears on the console or in the system log, contact your Cisco technical support representative,
and provide the representative with the gathered information.
Error Message %CAPI-2-NOT_ENOUGH_MEMORY_FOR_XL: Not enough memory ([dec]K) for
Feature Card [chars] ([dec]), which has minimum memory requirement of [dec]K
Explanation
The XL EARL daughter card requires a minimum amount of memory. If memory size
is less than the minimum requirement, system operations might be affected.
Recommended Action Upgrade the memory to reach the minimum size requirement.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco III - Supervisor Engine III and is the answer not in the manual?

Cisco III - Supervisor Engine III Specifications

General IconGeneral
BrandCisco
ModelIII - Supervisor Engine III
CategorySoftware
LanguageEnglish

Related product manuals