4. From the Target Type list, select Source, as shown in Figure 89.
Figure 89 Setting array properties: target type
.
5. To save your changes, click Save.
6. In the Security Check dialog box, enter the administrative password. (The default password is
migration.)
The mpx Manager displays a message indicating that the array properties have changed.
7. Click OK to close the message box.
8. To apply the changes and update the window before changing other array properties, click
Refresh.
Setting the array bandwidth
After you have changed the Target Type to Source, saved your changes, and refreshed the mpx
Manager (see Setting array properties in the GUI), the right pane for the array shows an additional
property, Array Bandwidth. Follow the procedure in this section to change the array’s bandwidth
setting for data transfers.
NOTE:
The array bandwidth displays and is editable only if the array target type is Source.
Offline Data Migration152