'Q' and the ENTER key to do so.
IP Address (IPv4 or IPv6) [0.0.0.0] fe80::217:a4ff:fe99:c279
Iteration Count (0=Continuously) [0 ] 10
Outbound Port (0=Mgmt, 1=GE1, 2=GE2, ...) [Mgmt ]
Size Of Packet (Min=1, Max=65486 Bytes) [56 ]
Pinging fe80::217:a4ff:fe99:c279 with 56 bytes of data:
Request timed out.
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.4ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.3ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.3ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.2ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.3ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.3ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.7ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.2ms
Reply from fe80::217:a4ff:fe99:c279: bytes=64 time=0.2ms
Ping Statistics for fe80::217:a4ff:fe99:c279:
Packets: Sent = 10, Received = 9, Lost = 1
Approximate round trip times in milli-seconds:
Minimum = 0.2ms, Maximum = 0.7ms, Average = 0.3ms
Quit
Exits the CLI and returns you to the login prompt (same as the exit command).
NoneAuthority
quit
Syntax
Example 1: The quit command behaves differently depending on whether you are at the chassis
management level or blade management level. At the chassis management level, quit returns you
to the login prompt. The following example shows the quit command for the chassis:
MPX200 <1>(admin) #> quit
(none) login:
At the blade management level, quit returns you to the chassis management level. The following
example shows the quit command for the blade:
MPX200 <1>(admin) #> quit
HP StorageWorks MPX200 #>
Reboot
Restarts the blade firmware.
Admin sessionAuthority
reboot
Syntax
Example:
MPX200 <1>(admin) #> reboot
Are you sure you want to reboot the System (y/n): y
System will now be rebooted...
Command referencecommand reference276

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6400/8400 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6400/8400 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6400/8400 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals