1. Perform zoning as follows:
a. Connect the Fibre Channel ports of the data migration appliance to a switch where the
storage controller ports are also logged.
b. Using switch management tools, create a zone, DM_Host_EMC.
c. In this zone, add the WWPN of the data migration appliance Fibre Channel ports and
storage controller ports.
d. Save the zoning information and activate the new zoning configuration.
2. Using Internet Explorer, open the Navisphere utility using the IP assigned to the storage controller.
The Enterprise Storage dialog box opens, as shown in Figure 145.
Figure 145 Viewing enterprise storage
.
3. Select the appropriate storage array, right-click the array name, and then click Connectivity
Status.
4. Select the WWPN associated with the data migration appliance, and then click Register.
MPX200 Multifunction Router 397