3.
mpathadm show lu logical-unit
This command displays details about a logical unit. Use this command to verify symmetric mode,
load balancing, and auto-failback settings, as well as path and target port information.
Example:
#mpathadm show lu /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Logical Unit: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
mpath-support: libmpscsi_vhci.so
Vendor: HP
Product: HSV300
Revision: 0005
Name Type: unknown type
Name: 600508b4000b15a200005000038e0000
Asymmetric: no
Current Load Balance: none
Logical Unit Group ID: NA
Auto Failback: off
Auto Probing: NA
Paths:
Initiator Port Name: iqn.1986-03.com.sun:01:sansun-s04,4000002a00ff
Target Port Name: 4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
b2.01.50014380025c4179
Override Path: NA
Path State: OK
Disabled: no
Initiator Port Name: iqn.1986-03.com.sun:01:sansun-s04,4000002a00ff
Target Port Name: 4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
b1.01.50014380025c417d
Override Path: NA
Path State: OK
Disabled: no
Target Ports:
Name: 4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
b2.01.50014380025c4179
Relative ID: 0
Name: 4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
b1.01.50014380025c417d
Relative ID: 0
Managing and troubleshooting Solaris iSCSI multipath devices
For details on managing and troubleshooting Solaris iSCSI multipath devices, see the Solaris System
Administration Guide: Devices and File Systems, available at http://dlc.sun.com/pdf/817-5093/
817-5093.pdf.
Configuring Microsoft MPIO iSCSI devices
For Microsoft MPIO, the load-balance policies apply to each LUN individually. To display and modify
the LUN load-balance policy (Figure 56):
1. Start the Microsoft iSCSI Control Panel applet.
2. Select the Target tab.