e. Test the connection from the initiator to the iSNS server by clicking Verify iSNS. If successful,
click Save.
If necessary, from the iSNS server, make the appropriate edits to add the Xtend SAN iSCSI
Initiator to any iSNS discovery domains that include MPX iSCSI targets.
f. Click Discover Targets, and then click Discover by iSNS.
A list of MPX targets appears under Discovered Targets (Figure 43).
Figure 43 Discovered targets
.
NOTE:
The MPX iSCSI port may present several iSCSI targets to the Xtend SAN iSCSI Initiator.
Select only one target from the list.
g. Select the newly added target under Host name in the left pane.
h. Select the Visible check box to allow the initiator to display the target status (Figure 44).
i. Select the Auto Login check box to configure the initiator to automatically log in to the iSCSI
target at system startup.
MPX200 iSCSI configuration rules and guidelines68

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6400/8400 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6400/8400 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6400/8400 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals