Table 48 shows new Fibre Channel zones information to configure MPX200 for data migration and
to migrate the data. The MPX200 Fibre Channel ports are configured with source and destination
arrays.
Table 48 Example B: Pre-migration Fibre Channel zoning information
Server, MPX200, storage nameZone members (WWPNs)FC zone
name
FC switch and
IP Address
MPX200, FC1
nl
SRC-Array-ABC: P1
nl
SRC-Array-ABC: P3
nl
DEST-Array-XYZ: P1
nl
DEST-Array-XYZ: P3
21-00-00-C0-DD-C0-88-81
nl
50-06-01-60-41-E0-18-94
nl
50-06-01-62-41-E0-18-94
nl
50-00-1F-E1-50-06-22-A1
nl
50-00-1F-E1-50-06-22-A2
Zone-A-DMFC-SW-1
nl
10.5.3.1
MPX200: FC2
nl
SRC-Array-ABC: P2
nl
SRC-Array-ABC: P4
nl
DEST-Array-XYZ: P2
nl
DEST-Array-XYZ: P4
21-00-00-C0-DD-C0-88-82
nl
50-06-01-61-41-E0-18-94
nl
50-06-01-63-41-E0-18-94
nl
50-00-1F-E1-50-06-22-A8
nl
50-00-1F-E1-50-06-22-A9
Zone-B-DMFC-SW-2
nl
10.5.3.2
Table 49 shows an example of post-migration Fibre Channel zoning information:
Table 49 Example: Post-migration Fibre Channel zoning information
Server, MPX200, stor-
age name
Zone members (WWPNs)FC zone nameFC switch and IP Ad-
dress
HR-Dept: P1
nl
iPortal: P1
nl
Sales: P1
nl
DEST-Array-XYZ: P1
nl
DEST-Array-XYZ: P3
21-00-00-C0-DD-C0-8A-D7
nl
21-00-00-C0-DD-C0-55-57
nl
21-00-00-C0-DD-C0-60-66
nl
50-00-1F-E1-50-06-22-A1
nl
50-00-1F-E1-50-06-22-A2
Zone-AFC-SW-1
nl
10.5.3.1
HR-Dept: P2
nl
iPortal: P2
nl
Sales: P2
nl
DEST-Array-XYZ: P2
nl
DEST-Array-XYZ: P4
21-00-00-C0-DD-C0-8A-D8
nl
21-00-00-C0-DD-C0-55-58
nl
21-00-00-C0-DD-C0-60-67
nl
50-00-1F-E1-50-06-22-A8
nl
50-00-1F-E1-50-06-22-A9
Zone-BFC-SW-2
nl
10.5.3.2
Assigning LUNs to the MPX200 for data migration
For successful completion of data migration, you must assign source and destination LUNs to the
MPX200 using storage array management tools. The MPX200 appears as a host to the array controller.
This section provides procedures for using some of the array management tools to assign LUNs.
Assigning LUNs from an MSA2012fc array
HPStorage Vendor
MSA2012fc arraysArray Model
Storage Management Utility user interfaceLUN Assignment Tool
MPX200 Multifunction Router 379

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6400/8400 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6400/8400 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6400/8400 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals