3-12 Basic Operation Models 2500 and 2502 User’s Manual
Numeric entry — When the edit mode is entered, the cursor is located on the most
significant digit of the value. From this position, you can key in the value using the
number keys (0 through 9). After each number is keyed in, the cursor moves one
position to the right. If desired, you can use the EDIT and keys to place the
cursor on a digit to be changed, and press the appropriate number key. The cursor
does not have to be on the polarity sign of the value to change polarity. If the 0000
(MENU) key is pressed, the source value will be clear to 0V.
4. To edit the source on the other channel, press SRC1 or SRC2 to select it, and repeat
steps 2 and 3.
5. When finished editing source value(s), press ENTER or wait six seconds to exit from
the edit mode.
Step 3. Turn source outputs on.
Turn the voltage source outputs on by pressing the ON/OFF OUTPUT key. The red OUT-
PUT indicator will turn on to indicate that both channel outputs are on.
Step 4. Observe readings on the display.
Observe the current readings in the channel 1 (top left) or channel 2 (top right) display
field as appropriate. If in the MSR1 or MSR2 display mode, use the DISPLAY TOGGLE
key to toggle between channels if desired, or use the CHANNEL SELECT key to select
the displayed channel.
Step 5. Turn source output off.
When finished, turn both voltage source outputs off by pressing the ON/OFF OUTPUT
key. The red OUTPUT indicator light will turn off.
Remote command measurement procedure
Basic measurement procedures can also be performed via remote by sending appropriate
commands in the right sequence. The following paragraphs summarize the basic com-
mands and give a simple programming example.
Basic measurement and voltage source commands
Table 3-6 summarizes basic measurement and voltage source commands. See Section 17
for more information on using these commands as well as many other commands that con-
trol these functions.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

Table of Contents

Other manuals for Keithley 2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2500 and is the answer not in the manual?

Keithley 2500 Specifications

General IconGeneral
BrandKeithley
Model2500
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals