MAN B&W 6.03
Page 4 of 8
MAN Diesel
198 71 01-5.0MAN B&W L35Mc6-TII
List of Capacities for 8L35MC6-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
1 x TCR22-21
1 x TPL69-BA10
1 x MET42MA
-
-
-
1 x TCR22-21
1 x TPL69-BA10
1 x MET42MA
-
-
-
Pumps
Fuel oil circulation m³/h 2.7 2.7 2.7 N.A. N.A. N.A. 2.7 2.7 2.7 N.A. N.A. N.A.
Fuel oil supply m³/h 1.4 1.4 1.4 N.A. N.A. N.A. 1.4 1.4 1.4 N.A. N.A. N.A.
Jacket cooling m³/h 45.0 45.0 45.0 N.A. N.A. N.A. 45.0 45.0 45.0 N.A. N.A. N.A.
Seawater cooling * m³/h 165.0 165.0 160.0 N.A. N.A. N.A. 165.0 160.0 160.0 N.A. N.A. N.A.
Main lubrication oil * m³/h 120.0 125.0 125.0 N.A. N.A. N.A. 120.0 125.0 125.0 N.A. N.A. N.A.
Central cooling * m³/h - - - - - - 165 165 160 - - -
Scavenge air cooler(s)
Heat diss. app. kW 2,020 2,020 2,020 N.A. N.A. N.A. 2,010 2,010 2,010 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 102 102 102 N.A. N.A. N.A.
Seawater flow m³/h 102 102 102 N.A. N.A. N.A. - - - N.A. N.A. N.A.
Lubricating oil cooler
Heat diss. app. * kW 490 450 425 N.A. N.A. N.A. 490 450 425 N.A. N.A. N.A.
Lube oil flow * m³/h 120.0 125.0 125.0 N.A. N.A. N.A. 120.0 125.0 125.0 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 63 63 58 N.A. N.A. N.A.
Seawater flow m³/h 63 63 58 N.A. N.A. N.A. - - - N.A. N.A. N.A.
Jacket water cooler
Heat diss. app. kW 800 800 800 N.A. N.A. N.A. 800 800 800 N.A. N.A. N.A.
Jacket water flow m³/h 45 45 45 N.A. N.A. N.A. 45 45 45 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 63 63 58 N.A. N.A. N.A.
Seawater flow m³/h 63 63 58 N.A. N.A. N.A. - - - N.A. N.A. N.A.
Central cooler
Heat diss. app. * kW - - - N.A. N.A. N.A. 3,300 3,260 3,240 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 165 165 160 N.A. N.A. N.A.
Seawater flow m³/h - - - N.A. N.A. N.A. 165 160 160 N.A. N.A. N.A.
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume m³ 2 x 1.5 2 x 1.5 2 x 1.5 N.A. N.A. N.A. 2 x 1.5 2 x 1.5 2 x 1.5 N.A. N.A. N.A.
Compressor cap. m³ 90 90 90 N.A. N.A. N.A. 90 90 90 N.A. N.A. N.A.
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume m³ 2 x 1.0 2 x 1.0 2 x 1.0 N.A. N.A. N.A. 2 x 1.0 2 x 1.0 2 x 1.0 N.A. N.A. N.A.
Compressor cap. m³ 60 60 60 N.A. N.A. N.A. 60 60 60 N.A. N.A. N.A.
Other values
Fuel oil heater kW 71 71 71 N.A. N.A. N.A. 71 71 71 N.A. N.A. N.A.
Exh. gas temp. °C 265 265 265 N.A. N.A. N.A. 265 265 265 N.A. N.A. N.A.
Exh. gas amount kg/h 43,600 43,600 43,600 N.A. N.A. N.A. 43,600 43,600 43,600 N.A. N.A. N.A.
Air consumption kg/h 11.9 11.9 11.9 N.A. N.A. N.A. 11.9 11.9 11.9 N.A. N.A. N.A.
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01h: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR