MAN B&W 14.04
Page  of 
MAN Diesel
MAN B&W S35MC7, L35MC6 198 62 21-9.0
Table 14.04.01: Electric motor for auxiliary blower
The installed power of the electric motors are based on a voltage supply of 3x440V at 60Hz.
The electric motors are delivered with and tted onto the engine.
Electric Motor for Auxiliary Blower
Number of
cylinders
Number of auxiliary
blowers
Required power/blower
kW
Installed power/blower
kW
5
2
5 8
6 20 2
7 20 2
8 26 26
9 26 26
0
Data is available on request
2
The number of auxiliary blowers in a propulsion
plant may vary depending on the actual amount of
turbochargers as well as space requirements.
For typical engine congurations, the required
power of the auxiliary blowers as well as the in-
stalled size of the electric motors are listed in Ta-
ble 4.04.0.