MAN B&W 6.03
Page 7 of 8
MAN Diesel
MAN B&W L35Mc6-TII 198 71 01-5.0
List of Capacities for 11L35MC6-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
2 x TCR22-21
2 x TPL65-BA10
2 x MET33MA
-
-
-
2 x TCR22-21
2 x TPL65-BA10
2 x MET33MA
-
-
-
Pumps
Fuel oil circulation m³/h 3.6 3.6 3.6 N.A. N.A. N.A. 3.6 3.6 3.6 N.A. N.A. N.A.
Fuel oil supply m³/h 1.9 1.9 1.9 N.A. N.A. N.A. 1.9 1.9 1.9 N.A. N.A. N.A.
Jacket cooling m³/h 62.0 62.0 62.0 N.A. N.A. N.A. 62.0 62.0 62.0 N.A. N.A. N.A.
Seawater cooling * m³/h 235.0 225.0 225.0 N.A. N.A. N.A. 225.0 220.0 220.0 N.A. N.A. N.A.
Main lubrication oil * m³/h 165.0 165.0 160.0 N.A. N.A. N.A. 165.0 165.0 160.0 N.A. N.A. N.A.
Central cooling * m³/h - - - - - - 230 225 220 - - -
Scavenge air cooler(s)
Heat diss. app. kW 2,780 2,780 2,780 N.A. N.A. N.A. 2,760 2,760 2,760 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 141 141 141 N.A. N.A. N.A.
Seawater flow m³/h 140 140 140 N.A. N.A. N.A. - - - N.A. N.A. N.A.
Lubricating oil cooler
Heat diss. app. * kW 740 630 580 N.A. N.A. N.A. 740 630 580 N.A. N.A. N.A.
Lube oil flow * m³/h 165.0 165.0 160.0 N.A. N.A. N.A. 165.0 165.0 160.0 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 89 84 79 N.A. N.A. N.A.
Seawater flow m³/h 95 85 85 N.A. N.A. N.A. - - - N.A. N.A. N.A.
Jacket water cooler
Heat diss. app. kW 1,100 1,100 1,100 N.A. N.A. N.A. 1,100 1,100 1,100 N.A. N.A. N.A.
Jacket water flow m³/h 62 62 62 N.A. N.A. N.A. 62 62 62 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 89 84 79 N.A. N.A. N.A.
Seawater flow m³/h 95 85 85 N.A. N.A. N.A. - - - N.A. N.A. N.A.
Central cooler
Heat diss. app. * kW - - - N.A. N.A. N.A. 4,600 4,490 4,440 N.A. N.A. N.A.
Central water flow m³/h - - - N.A. N.A. N.A. 230 225 220 N.A. N.A. N.A.
Seawater flow m³/h - - - N.A. N.A. N.A. 225 220 220 N.A. N.A. N.A.
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume m³ 2 x 1.5 2 x 1.5 2 x 1.5 N.A. N.A. N.A. 2 x 1.5 2 x 1.5 2 x 1.5 N.A. N.A. N.A.
Compressor cap. m³ 90 90 90 N.A. N.A. N.A. 90 90 90 N.A. N.A. N.A.
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume m³ 2 x 1.0 2 x 1.0 2 x 1.0 N.A. N.A. N.A. 2 x 1.0 2 x 1.0 2 x 1.0 N.A. N.A. N.A.
Compressor cap. m³ 60 60 60 N.A. N.A. N.A. 60 60 60 N.A. N.A. N.A.
Other values
Fuel oil heater kW 94 94 94 N.A. N.A. N.A. 94 94 94 N.A. N.A. N.A.
Exh. gas temp. °C 265 265 265 N.A. N.A. N.A. 265 265 265 N.A. N.A. N.A.
Exh. gas amount kg/h 60,000 60,000 60,000 N.A. N.A. N.A. 60,000 60,000 60,000 N.A. N.A. N.A.
Air consumption kg/h 16.3 16.3 16.3 N.A. N.A. N.A. 16.3 16.3 16.3 N.A. N.A. N.A.
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01k: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR