MAN B&W 18.04
Page 7 of 7
MAN Diesel
MAN B&W MC/MCC engines 198 62 364.2
Shut down for AMS and UMS – Class and MAN Diesel requirements
1 Indicates that the sensor is required.
The sensors in the MAN Diesel column are included for Unattended Machinery Spaces (UMS), option: 4 75 127.
The sensor identication codes and functions are listed in Table 18.07.01.
The tables are liable to change without notice, and are subject to latest class requirements.
Or alarm for overheating of main, crank and crosshead bearings, option: 4 75 14.
See also Table 18.04.0: Slow down functions for UMS
* Or slow down
Table 18.04.04: Shut down functions for AMS and UMS, option: 4 75 124
ABS
BV
CCS
DNV
GL
KR
LR
NK
RINA
RS
IACS
MAN Diesel
Sensor and
function Point of location
1 1 1 1* 1 1 1 1 1 1 1 1 PS/PT 8109 Z Lubricating oil inlet to main engine and thrust
bearing
1 1 1 1* 1 1 1 1 1 1 1 1 ZT 4020 Z Engine overspeed, incorporated in
Engine Control System
1 1 1 1 1 1 1 1 TE/TS 8107 Z Thrust bearing segment
1 PS/PT 8402 Z Jacket cooling water inlet
* 1 XS 881 Z Oil mist in crankcase/cylinder
International Association of Classication Societies
The members of the International Association of Classication Societies, IACS, have agreed that the stated sensors are
their common recommendation, apart from each class’ requirements.
The members of IACS are:
ABS American Bureau of Shipping
BV Bureau Veritas
CCS China Classication Society
DNV Det Norske Veritas
GL Germanischer Lloyd
KR Korean Register
LR Lloyd’s Register
NK Nippon Kaiji Kyokai
RINA Registro Italiano Navale
RS Russian Maritime Register of Shipping
and the assosiated member is: