5.9 Analog Monitor
The drive provides 2-channel analog monitor output, for drive gain tuning or internal status
parameter monitoring.
Figure 36. Analog Monitor
5.9.1 Related Objects
Index
Sub
Index
Name
Variable
Format
Accessibility
PDO
Allocation
Unit
0x2220 - Analog Monitor Output Mode UINT RW No -
0x2221 -
Analog Monitor Channel 1
Select
UINT RW No -
0x2222 -
Analog Monitor Channel 2
Select
UINT RW No -
0x2223 -
Analog Monitor Channel 1
Offset
DINT RW No -