P Series User Guide 262
Torque
(Force)
Speed
Max torque
0x280B
= Torque @Max torque / Max torque x 100
Torque
@Max speed
Max speed
0x280C
[Third Party Motor]Hall Offset
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
0 to 360
0
deg
RW
No
-
Yes
The hall sensor offset may vary depending on the manufacture. Please check the
hall sensor offset before setting.
9.1.4 Index Objects
0x3000
Control Mode
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
commu
nication
address
Change
Property
Stor
e
UINT
0 to 9
0
-
RW
Servo Off
Yes
Set the drive’s position control mode.
Set Value
0
1
2
3
4
Pulse input position operation mode &
5
Pulse input position operation mode
6
Pulse input position operation mode
7
8
9
www.comoso.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker P Series and is the answer not in the manual?

Parker P Series Specifications

General IconGeneral
BrandParker
ModelP Series
CategoryServo Drives
LanguageEnglish

Related product manuals