0x2015 - U Phase Current Offset INT RW No 0.1%
0x2016 - V Phase Current Offset INT RW No 0.1%
0x2017 - W Phase Current Offset INT RW No 0.1%
Table 95. Phase Current Offset Related Objects
7.1.9 Software Reset
This function resets the servo drive with the software. Software reset means restarting the
drive’s program, achieving an effect similar to resupplying the power.
This function can be used in the following cases.
Parameters which requires power are changed
Drive need to be restarted when unable reset alarm is set off.
7.1.10 Commutation
Commutation functions for acquiring initial angle information of the motor. When using a
motor without the hall sensor, the initial angle information needs to be acquired before
operation.
Related Objects
Index
Sub
Index
Name
Variable
Format
Accessibility
PDO
Allocation
Unit
0x2019
- Linear Scale Resolution UINT RW No nm
0x201A
- Commutation Method UINT RW No -
0x201B
- Commutation Current UINT RW No 0.1%
0x201C
- Commutation Time UINT RW No ms
Table 96. Commutation Related Objects
www.comoso.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker P Series and is the answer not in the manual?

Parker P Series Specifications

General IconGeneral
BrandParker
ModelP Series
CategoryServo Drives
LanguageEnglish

Related product manuals