Parker Hannifin
P Series User Guide 77
4.3 Communication Address Table
4.3.1 System Configuration Parameters
parameter
name
parameter
No.
Variable
Format
Default
Value
Min Max Unit Accessibility
decimal hexadecimal
8192 0x2000 Motor ID 0x2000 UINT 13 1 9999 - RW
8193 0x2001
0x2001 UINT 1 0 99 - RW
8194 0x2002
Pulse per
0x2002 UDINT 4096 0 1073741824 pulse RW
8196 0x2004 Node ID 0x2003 UINT - 0 65535 RO
8197 0x2005
Direction
0x2004 UINT 0 0 1 - RW
8198 0x2006
Encoder
0x2005 UINT 0 0 1 - RW
8199 0x2007
Fail Check
0x2006 UINT 0 0 255 - RW
8200 0x2008
Fail Check
0x2007 UINT 20 0 5000 ms RW
8201 0x2009
Display
0x2008 UINT 0 0 100 - RW
8202 0x200A
Brake
Resistor
0x2009 UINT 0 0 1 - RW
8203 0x200B
Brake
Resistor
Derating
0x200A UINT 100 0 200 % RW
8204 0x200C
Brake
Resistor
0x200B UINT 0 0 100 ohm RW
8205 0x200D
Brake
Resistor
0x200C UINT 0 0 30000 watt RW
8206 0x200E
of
Regeneration
Brake
0x200D UINT 100 1 50000 watt RW
8207 0x200F
Time @
Peak Power
of
Regeneration
Brake
0x200E UINT 5000 1 50000 ms RW
8208 0x2010
0x200F UINT 100 10 120 % RW
8209 0x2011
Warning
0x2010 UINT 50 10 100 % RW
8210 0x2012
0x2011 UINT 10 0 1000 ms RW
8211 0x2013
Brake
0x2012 UINT 0 0 3 - RW
8212 0x2014
0x2013 UINT 1 0 1 - RW