Parker Hannifin
P Series User Guide 23
2.1 Environment
The PD drive operates in an ambient temperature range of 0°C (32°F) to 50°C (122°F)
ambient air temperature for all models.
Items
Environment
Requirements
Notes
Ambient
Temperature
0∼50[℃]
Caution
Please attach the cooling fan to the control panel, so
that the temperature does not exceed the workable
temperature.
Surrounding
Humidity
90[%]RH or
below
Caution
Freezing or condensation inside the drive due to long-
term non-use may damage the drive. When operating
after non-use, please remove water before operating.
External
Vibration
Vibration
Acceleration
4.9[㎨] or below
Excessive vibration may shorten the life cycle of the
bearings
Environmental
Requirements
No exposure to direct sunlight
No corrosive/flammable gas
No oil or dust
In case of a closed space, adequate ventilation
Table 3. Drive Installation Environment