0x2304 - Program Jog Operation Speed 1 INT RW No rpm
0x2305 - Program Jog Operation Speed 2 INT RW No rpm
0x2306 -
Program Jog Operation Speed 3
INT RW No rpm
0x2307 -
Program Jog Operation Speed 4
INT RW No rpm
0x2308 - Program Jog Operation Time 1 UINT RW No ms
0x2309 -
Program Jog Operation Time 2
UINT RW No ms
0x230A
-
Program Jog Operation Time 3
UINT RW No ms
0x230B
-
Program Jog Operation Time 4
UINT RW No ms
Table 90. Program Jog Operation Related Objects
7.1.3 Alarm Record Detection
This function deletes all alarm code history Stored in the drive. The alarm history of the
newest alarm and up to 16 previous alarms is Stored in the drive.
The alarm history can be viewed at0x2702:01~16, as shown below. The newest recent
alarm is displayed at 0x2702:01.