EasyManuals Logo
Home>Parker>Servo Drives>P Series

Parker P Series User Manual

Parker P Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #282 background imageLoading...
Page #282 background image
Parker Hannifin
P Series User Guide 280
0x60FF
Target Speed
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
DINT
–2147483648 to
2147483647
0 UU/s RW Yes
At all
times
No
Set the target speed at PV mode and CSV mode.
0x6502
Supported Drive Modes
ALL
Variable
Format
Setting Range
Default
Value
Unit
Accessi
bility
PDO
Allocation
Change
Property
Store
UDINT -
0x000003A
D
- RO No - No
Show the modes supported by the drive.
bit
Supported Modes
Description
-1
IP (Indexing Position/Pulse Input
Position)
1: Supported
0
PP (Profile Position)
0: Not supported
1
Vl (Speed)
0: Not supported
2
PV (Profile Speed)
0: Not supported
3
PT (Torque Profile)
0: Not supported
4
Reserved
0
5
HM (Homing)
1: Supported
6
IP (Interpolated Position)
0: Not Supported
7
CSP (Cyclic Synchronous Position)
0: Not supported
8
CSV (Cyclic Synchronous Speed)
0: Not supported
9
CST (Cyclic Synchronous Torque)
0: Not supported
10 to 31
Reserved
0
Table 113. Supported Modes
www.comoso.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker P Series and is the answer not in the manual?

Parker P Series Specifications

General IconGeneral
BrandParker
ModelP Series
CategoryServo Drives
LanguageEnglish

Related product manuals