10.19
Battery and Electrical Systems
10
Security System: Changing Pass code
NOTE: Use the MODE button on the cluster when
performing procedure on models featuring the
analog/digital instrument cluster.
To change the current security code to a new code,
p
erform these steps:
NOTE: The instrument cluster illustrations on the
f
ollowing pages reference the 000 default security
code. Use the owner’s current security code.
1. Start the engine and lock the parking brake.
2. Lock and then unlock the security function on the
in
strument cluster using the existing pass code.
3. Immediately after unlocking security, press and hold
the MOD
E button to display the ENTER CODE
screen.
• SEL = Advances up 1 digit (0 to 9 to 0)
• MODE = Enter and move 1 digit to right
4. When ENTER CODE displays, use the MODE and
SEL button
s to select and accept each digit of the new
security code.
5. After pressing MODE to accept th
e third digit, the new
code and CODE SET will display if the system
accepted the new code. If successful, this screen will
not be displayed again.
6. Record the new security code in a safe place (Owner’s
M
anual or Customer RO) for future reference.
Security System: User Notes
• Security system activation requires an authorized
Polaris dealer using Digital Wrench® to turn on the
function in the ECU.
• First time use requires an initialization procedure
to
turn on the security function in the instrument
cluster.
• Holding the brake lever closed and pressing the
MODE and
SEL buttons for 3 seconds will bring up
the security display on the instrument cluster.
• If the brake lever is not held while pressing the
M
ODE and SEL buttons for 3 seconds, the
instrument cluster will start the record/playback
data logging function.
• Pressing the MODE button w
ill accept the selected
digit and move to the next digit. After entering the
third digit, pressing MODE a fourth time will enter
the code.
• Pressing the SEL button advances each digit up
from 0 to 9 t
hen back to 0.
• If the engine is running and security is locked, the
ECU
will shut the engine off when the engine
temperature is above 120°F (49°C) for 60
seconds.
• The instrument cluster retains the last
p
rogrammed security pass code. Disabling and
enabling the security function in the ECU does not
change the code in the instrument cluster. If the
pass code is unknown or BAD CODE is displayed
perform the Reset Pass code Procedure to reset
the code back to 000.
• Reflashing the ECU using the Engine Controller
Rep
rogramming function disables the security
function. Perform the Security Enable procedure
after reflashing the ECU.