283
The memory recall section switches to display the
selected bank.
4
Press the button for the target register to recall.
The register button is lit orange and the snapshot is
reca
lled.
Snapshot for a region other than a
switcher bank
1
Display the [Snapshot] taskbar.
Snapshot recall/store mode is activated.
2
Press the [Recall/Store] button.
The [Recall/Store Register] window appears.
3
Set the button for the target region to the on state.
You can select multiple regions.
For details about the display in the region display
sec
tion, see “Region display section” (page 283).
Select a tab to change the region to display.
[ME] tab: Swi
tcher bank regions
[User] tab: User
regions
[DME] tab: DM
E regions
[External Device] tab: E
xternal device regions
The first selected region becomes the reference
r
egion.
To select all regions configured beforehand
Set the [All Regions] button to the on state.
For details about setting the regions selected
si
multaneously, see “Setting Regions Selected
Simultaneously” (page 402).
The region selection is common for snapshots and
effect
timelines.
4
Press the [Recall] button.
5
Enter a register number in the numeric keypad area.
For details about selecting a register, see “Selecting
a register” (page 283).
To add the auto transition temporary attribute
Set [Auto Trns] in the numeric keypad area to the on
st
ate.
To add the effect dissolve temporary attribute
Set [Effect Diss] in the numeric keypad area to the on
st
ate.
In the [Recall/Store Register] window, it is not
possi
ble to add the cross-point hold temporary
attribute.
You can use the bus override function and the cross-
poi
nt button row cross-point hold function.
For details, see “Cross-Point Hold” (page 90).
6
Press [Enter].
The specified register is recalled.
To undo a register recall
To undo a recall immediately after recalling a register,
pr
ess the [Undo] button.
To set the duration for an effect dissolve
te
mporary attribute
You can set the duration for an effect dissolve temporary
at
tribute for each region.
Select the target region to set, press the [Temp Diss
Dur
ation] button, and enter a duration (number of frames)
for the effect dissolve in the numeric keypad area.
Selecting a register
Select a register using the numeric keypad area at the
bot
tom right of the [Recall/Store Register] window.
Enter a register number in the numeric keypad area and
pr
ess [Enter] to apply the setting.
When you enter a register number, the register number
and t
he following information appears on the numeric
keypad area display.
e: The register is empty for the currently selected region.
E: The register is empty for all selectable regions.
L: The register is locked.
To search for an empty register, press [.] (period).
To search for an empty register common to all selectable
reg
ions, press [.] (period) again.
Searching for an empty register is enabled only when
savi
ng a snapshot.
Region display section
The region display section at the top right of the [Recall/
St
ore Register] window shows the region selection status.
The selected regions are displayed in white characters.
The
reference region is displayed highlighted.
Saving a Snapshot
Switcher bank region snapshot
The same memory recall buttons as in the memory recall
section of the Flexi Pad control block are displayed in the
Common > Snapshot menu of the switcher bank. The
Note
Note
Note